CoolCell® FTS30 Cell Freezing Container for 30 x 1ml or 2ml Cryo Tubes – Witec AG

Art No | BCS-170T
from 680.00 CHF

CoolCell ​​​​​​Cell Freezing Containers for controlled-rate alcohol-free cell freezing provide a highly reproducible -1℃/minute freezing rate when placed in a -80℃ freezer, with no alcohol or fluids required.

Description

Alcohol-free CoolCell FTS30 Cell Freezing Container for 30 x 1ml or 2ml Cryo Tubes ensure controlled-rate -1℃/minute cell freezing in a -80℃ freezer.

  • No alcohol or fluids required
  • Consistent heat removal through freezing period
  • Unbreakable, easy and safe to open when frozen
  • For use with stem cells, primary cells and cell lines

CoolCell ​​​​​​Cell Freezing Containers for controlled-rate alcohol-free cell freezing provide a highly reproducible -1℃/minute freezing rate when placed in a -80℃ freezer, with no alcohol or fluids required. The patent-pending Cell Freezing Container technology utilizes a thermo-conductive alloy core and highly-insulative outer material to control the rate of heat removal to provide reproducible cell cryopreservation. The insulative outer housing and thermo-conductive solid state core ensure consistent heat removal to all vials throughout the freezing period

Cell Freezing Containers can replace isopropanol-based freezing containers such as Mr. Frosty by ThermoFisher Scientific and others, which can consume up to 12l per year of IPA and cost hundreds of dollars per unit per year to maintain.

Secure Sample Preservation

  • No variability in freeze rate, all vials have uniform freeze rate
  • Quick removal of frozen vials due to exposed vial tops, and removable vial module

Ease & saftey of Use

  • Unbreakable
  • Ergonomic lid comes off easily when frozen
  • Not cold to the touch when removed from -80°C freezer
  • Quick reuse time: the containers are ready to use again after 5 minutes

Competitive & Cost Saving Option

  • The units deliver comparable results to expensive programmable freezers
  • No fluids (e.g. alcohol) or precooling needed, can save 12l/unit of IPA per year
  • No on-going cost due to elimination of hazardous solvents or alcohol purchase and disposal

Broad Cell Compatibilty

  • Primary cells, including WBCs, human cardiac, muscle, mouse
  • Cell lines, including CHO, LnCap, HTB77, A549, HeLa
  • Stem cells, including human and mouse embryonic, breast and colon cancer, preadipocytes, progenitor, human endothelial, glioblastoma

Supplier

AZENTA - BioCision
show all products

Specifications

Container dimensions (diameter x H)

16.5 x 11.5cm

Well diameter

12.3mm

For use with

30 standard 1.0 to 2.0ml cryogenic vials, 1.0ml fill per vial