The NEW NanoDrop™Ultra Spectrophotometers and Fluorometers represent the next generation of microvolume detection
Description
These cutting-edge instrument delivers exceptional accuracy and sensitivity for nucleic acid and protein analysis with sample volumes as low as 1.0 μL.
The NanoDrop Ultra is designed to operate seamlessly within workflows across a wide range of fields, including genomics, proteomics, molecular biology, biotechnology, pharmaceutical, and life sciences research. It provides unparalleled precision, efficiency, and reliability in one compact device.
Quantify and qualify DNA, RNA, and protein samples in seconds with only 1–2 μL, and obtain full spectral data before you decide to use samples in downstream applications. Cuvette compatible models are available for additional flexibility.
Avoid costly setbacks in your workflow with an understanding of sample quality like never before using the Thermo Scientific™ NanoDrop™ Ultra Microvolume UV-Vis Spectrophotometers Fluorometers.
Innovative Thermo Scientific™ Acclaro™ Sample Intelligence technology is built into every instrument for improved measurement accuracy and contaminant identification.
Four instruments to meet the needs of all labs:
- NanoDrop Ultra
Pedestal absorbance - NanoDrop UltraC
Pedestal absorbance | Cuvette absorbance
- NanoDrop Ultra FL
Pedestal absorbance | Pedestal Fluorescence - NanoDrop UltraC FL
Pedestal absorbance | Cuvette absorbance | Pedestal Fluorescence
NanoDrop Ultra FL measures fluorescence

Fluorescence assay for dsDNA and RNA quantitation
- Pre-programmed dsDNA and RNA applications
dsDNA BR, dsDNA HS, RNA HS - Fluorometer mode for alternative dyes
• Blue Excitation: 430 – 495 nm
• Red Excitation: 600 – 645 nm - Reagent calculator aides in preparing reaction
qPCR recipe calculator aides in calculations



- Users select their desired qPCR kit on the dsDNA Setup page.
- A Kit Editor allows for entry of custom kit information, and these custom kits then appear in the kit selection dropdown menu.
- The software streamlines qPCR sample preparation by automatically calculating recommended dilution steps.
- It intelligently detects highly concentrated samples and suggests appropriate dilutions to ensure optimal reaction conditions.
- While the software defaults to the manufacturer’s recommended final template concentration, users retain full control and can easily adjust this value as needed.
- The new feature includes a helpful tooltip walkthrough
Acclaro Sample Contaminant Analysis Update
Differentiating DNA from RNA uses multiple wavelengths; now for Plant and Bacteria


Specifications
Wavelength Range |
190 – 850nm |
Absorbance Range (10mm equivalent) |
0.02 – 550 Abs |
dsDNA Lower Limit |
1 ng/μL |
dsDNA Upper Limit |
27’500 ng/μL |
DNA/RNA Differentation |
|
21 CFR Part 11 |
LC or PC |
Warranty |
2 years |
Fluorescence |
Blue & Red LEDs |
qPCR Recipe Calculator |
Yes |
LIMS Export |
RESTful API |
Battery |
External USB-C |
Print to PDF |
Yes |
PC Control Software |
Free |
Cuvette Temperature |
37°C ± 0.5°C |
Built-in Memory |
64GB |
Custom Methods Editor on LC |
Yes |
PC Connection |
USB or Ethernet |