NEWTON 7.0 FT900 - in Vivo Imaging – Witec AG

Art No | 1211 9790 1
ask for a quote
ask for a quote

The Ultimate Dual-Camera Solution for VIS, NIR, and NIR-II In Vivo Imaging

 

Description

The NEWTON 7.0 FT900 is a powerhouse of optical innovation, engineered to push the boundaries of preclinical discovery. Featuring a sophisticated dual-camera architecture, this system delivers ultimate sensitivity and the deepest insights into the NIR-II / SWIR spectrum, ensuring that no detail goes unnoticed in your research.

The Newton series offers advanced bioluminescence, fluorescence multispectral imaging, and optional X-Ray capabilities for a wide range of in-vivo applications. Designed as an all-in-one solution, it provides a non-ionizing and non-invasive gateway to visualizing complex biological processes in real-time.
  • Broad Spectrum Detection: Seamlessly transition between the visible, near, and short-wave infrared spectrums (VIS/NIR/NIR-II).
  • Dual-Camera Precision: Optimized for scientists seeking exceptional performance and high-resolution deep-tissue imaging.
  • Anatomical Context: Optional integrated X-Ray provides structural overlays for precise localization of signals.
  • Non-Invasive Monitoring: Track disease progression and molecular activity over time without compromising animal welfare.

 

Get inspired and learn more about state-of-the-art in vivo imaging:
Vilber | NEWTON

Perfect Light Control

The Newton imagers feature an advanced RGB light shutter. With the shutter closed, the system provides complete darkness for highly sensitive applications such as bioluminescence or in vivo chemiluminescence imaging, avoiding any interference from residual visible light. When opened, it delivers powerful, uniform RGB illumination for high-quality VIS imaging. This precise light control is particularly valuable for your longitudinal studies, multiplex fluorescence experiments, and low-signal luminescence assays, where even minimal light contamination could compromise quantitative results.

Light-Control-sx

Dual-Camera

 

Explore what conventional imaging can’t reach with the Newton FT-900. Designed around a dual-camera architecture – one dedicated to VIS/NIR imaging and a second, ultra-sensitive SWIR-camera – it ensures reduced image acquisition times and real-time, low-noise imaging. Not only will you see blood flow, tumors, and even single cells in vivo with unrivalled precision, but you’ll also achieve absolute quantification thanks to our NIST-traceable calibrated optics.

16-bit-CCD-Camera
SWIR-CCD-Camera

Testimonial

Customer from University Hospital Basel | Brain Tumor Immunotherapy:

„The high sensitivity of the Newton enables us to detect the intracranial tumors more precisely and much earlier, which improved our experimental treatment regimens significantly“

Newton In-Vivo Imaging

Lungs presenting micro & macro metastases from MDA-MB-231 expressing GFP-Luciferase – Image property of University Basel

Newton In-Vivo Imaging

Image property of University Basel

Powerful Fluorescence Excitation

The Newton 7.0 offers 8 excitation channels in the visible RGB and near infrared spectrums. The very tight LED spectrum is additionally constrained with a very narrow excitation filter; these excitation sources are categorized as a Laser Class II due to their intense power. Movement of the excitation source over the entire FOV ensures consistent and reproducible results over the course of a longitudinal study.

Full Spectrum Tunability

8 excitation channels and 8 emission filters are available to cover the complete spectrum from Blue to infra-red.

Narrow bandpass filters are used for both excitation and emission to reduce cross talk between dies, allowing for up to 3 dyes to be imaged simultaneously.

Macro-imaging to large throughput studies

Vilber’s intelligent darkroom architecture allows for fully automated movement of the camera (Z-axis) and animal pad (X/Y axis) to move through both the macro imaging FOV (6x6cm) to the full FOV (20x20cm) for imaging up to 5 mice.

 

Spectral Unmixing

Spectral unmixing is possible for both bioluminescence and fluorescence imaging when different luciferase enzymes or fluorescent dies are used.

The includes algorithms to remove crosstalk between the different signals, allowing for each channel to contain signal from only one reporter.

3D Optical Tomography

An integrated 3D tomography module allows both bioluminescence and fluorescence signals to be reconstructed in 3D and overlaid within a topographical model of the imaging subject.

For better understanding of anatomical and deeper tissue structures, the digital organ library allows for superimposition of the mouse organs and bones onto the topographical model.

 

State-or-the-art camera technology

  • Scientific grade 16-bit CCD
  • -90°C delta cooling
  • f/0.7 aperture
  • 10 megapixel image resolution
  • 4.8 Optical Density

The advanced camera and optics provide increased sensitivity to either bioluminescence or fluorescence signals, with a very low signal to noise ratio. The high optical density allows for samples with both very low and high signals to be imaged without saturation, allowing for quantifiable results.

Imaging Modes – Fluorescence

Easily detect fluorescent molecules and reporters at the picogram level in the tissue of interest using Vilber’s dynamic range of excitation emission wavelengths.

Newton Fluorescent molecules

Imaging Modes – Fluorescence

For deeper tissue penetration and reduction of autofluorescence background, infrared (IF) and near-infrared (NIR) molecules can also be imaged with Vilber.

Newton Fluorescent molecules IF-NIR

The below dyes can be used with the Newton 7.0 systems:

Newton Fluorescent molecules

Imaging Modes – Bioluminescence

Bioluminescence imaging can be used to detect luciferase-tagged molecules at the femtogram level.

 

Newton 7.0 Bioluminescence

Imaging Modes – Multispectral Imaging

Multispectral in vivo imaging is possible by using different luciferase enzyme/substrate pairs or by using different fluorescent dyes.

Signals can be overlaid within the same image, up to 3 reporters can be imaged simultaneously.

Newton 7.0 Multispectral Imaging

Imaging Modes – Longitudinal Imaging

Images acquired at different time points can be arranged to form a longitudinal image sequence. For example, a time series could be constructed from images acquired on different days following an experimental treatment.

The software then compares the image data throughout the experimental treatment.

 

Newton 7.0 Longitudinal Imaging

Applications – Arthritis

Inflammatory responses can be assessed using non-invasive fluorescence biomarker imaging in a preclinical model of rheumatoid arthritis.

 

 

Newton application Arthritis

Applications – Tumor Monitoring

Tumor progression can be monitored after establishment of orthotopic tumors in mice. The mouse brain was injected with 10,000 (fig.left ) and 50,000 (fig.right ) cancer cells expressing luciferase.

After a 6 weeks, tumors were formed, where signal was dependent on tumor cell injection quantity.

Newton Tumor Monitoring

Applications – Biodistribution

Using the Vilber imaging system, researchers investigated the biodistribution of doxorubicin hydrochloride-loaded nanogels in rats (Sprague–Dawley, 220–250 g), click here for the link to the article abstract. The fluorescent signal of DOX was detected and monitored over eight hours, seen right.

 

Newton Biodistribution

Applications – Biodistribution

The major organs were dissected 10 h after oral administration and observed ex vivo.

Signal quantification demonstrated that organs harvested from rats treated with doxorubicin hydrochloride-loaded nanogels group exhibited significantly higher retention of doxorubicin hydrochloride compared to rats treated with doxorubicin hydrochloride alone.

Newton Biodistribution Organs

Applications – Biodistribution

In vivo fluorescence imaging of FITC-BSA nanoparticle in the Turbot fish.

After 36 h, the heart and liver were dissected and visualized nanoparticle retention was identified.

 

Newton Biodistribution Fish

Applications – Gastrointestinal Pathologies

Bioluminescent enterotoxic E. coli (ETEC) is tracked through the mouse intestine, demonstrating the colonization dynamics across the GI tract. Click here for the link to the article abstract.

Streptomycin-treated BALB/c mice were inoculated with E. coli bacteria via gavage with pRMkluc-tagged ETEC and pRMkluc-tagged E. coli K-12.  Luciferin was administered intraperitoneally prior to imaging.

After inoculation, bioluminescence was localized to the small intestine. 48 hours post-inoculation, the bioluminescent signals indicated bacterial passage through the mouse intestine. Bioluminescent signals were detected in the mouse intestine up to 120 h post-inoculation.

After 120 h of E. coli infection, mouse gastrointestinal tracts were extracted to perform ex vivo imaging. Intestinal tract dissection included the esophagus to rectum.

ETEC were localized in the proximal mouse ileum approximately 6 cm from the cecum, whereas the E. coli K-12 ol signals were identified in the cecum and in the proximal colon.

 

Newton Gastrointestinal Pathologies

Applications – Infection Tracking

BALB/c mice were intraperitoneally inoculated with E. coli K-12 tagged with pRMkluc or E. coli K-12 tagged with pBR322 (incubated with luciferin). Click here for a link to the article abstract.

After 1 h of infection, bioluminescent signal emission from the animals was captured.

Mice infected with E. coli K-12 harboring pBR322 did not exhibit bioluminescent emission (Fig.B). However, mice infected with E. coli harboring pRMkluc emitted bioluminescent signals detected in the mouse inoculation zone (Fig.A).

Newton Infection Tracking

Applications – Toxicology

Screen localization dynamics of fluorescently-tagged drugs. Investigators injected a Cy5.5-tagged drug and tracked it’s spread systemically in the mouse.

 

 

 

 

Newton Toxicology

NEWTON Models

BT100 FT100 BT500 FT500
Camera DarQ-9 1” Scientific CCD Sensor 2160×2160 (4.6 MP) DarQ-9 1” Scientific CCD Sensor 2160×2160 (4.6 MP) DarQ-9 1” Scientific CCD Sensor 2160×2160 (4.6 MP) DarQ-9 1” Scientific CCD Sensor 2160×2160 (4.6 MP)
Cooling -90°C -90°C -90°C -90°C
Lens f/.070 f/.070 f/.070 f/.070
Bioluminescence Yes Yes Yes Yes
VIS/NIR Fluorescence upgradeable 400 > 900nm upgradeable 400 > 900nm
3D Optical tomography Yes Yes Yes Yes
Emission Filter-Wheel 11 positions 11 positions 11 positions 11 positions
Field Of View 12 x 12cm 12 x 12cm 6 x 6cm to 20 x 20cm 6 x 6cm to 20 x 20cm
Animal Capacity 1 or 3 mice 1 or 3 mice 5 mice / 3 rats 5 mice / 3 rats
Heated Stage Yes Yes Yes Yes
Anesthesia Station Optional Optional Optional Optional

Supplier

Vilber Lourmat S.A.
show all products

Specifications

Performance

Bioluminescence detection : femtogram level
Fluorescence detection : picogram level

Camera & Optics

Scientific grade CCD camera
Grade 0, zero defect
400-900nm / 4.8 O.D.
Image resolution: 10 megapixels
Native resolution: 2160×2160

Motorized V.070 lens: f:0.70
Minimum: 6x6cm
Maximum: 20x20cm

Animal Management

BIOSTHESIA gas anesthesia module
Heated table
Choice of animal breather for 1, 3 or 5 mice

Hardware Capabilities

Intelligent Darkroom concept
Fully-automatic system
• Motorized optical lens
• Motorized filter wheel
• Software controlled lighting
• Automatic visible lighting adjustment
• Auto-focus & Auto-exposure

Illumination & Filters

Epi-illumination
8 excitation channels from blue to IR
11 position filter wheel
Large choice of up to 9 customer made narrow
bandpass emission filters

Related products

If you continue we assume that you consent to receive all cookies on this website. More information

My Cart