ADAM MC2 - a new standard of Automated Cell Counter – Witec AG

Art No | ADAM-MC2
request only
request only

BRANDNEW! ADAM MC2 - Most Accurate Nucleus Cell Counter

Description

ADAM-MC2 is a new standard of automated fluorescence cell counter. ADAM stands for Advanced Detection and Accurate Measurement.

ADAM-MC2 utilizes sensitive fluorescence dye staining, LED optics and CMOS detection technologies to make the cell analysis more accurate and reliable. It measures the number of total cells, viable cells, non-viable cells and shows viability results.

Combined with a disposable microfluidic chip, the operation is now extremely simple, easy, and cost-effective.

ADAM-MC2 is a new standard of automated fluorescence cell counter.

ADAM MC2 - a new standard of Automated Cell Counter

Principle of Viability Measurement (PI-Staining Method)

After the samples are stained with fluorescent dye, propidium iodide, which intercalates DNA to stain the nucleus of target cells, ADAM-MC takes fluorescent images automatically. The obtained images are processed by image analysis software integrated inside the system.

ADAM MC2 - a new standard of Automated Cell Counter

Counting Aggregated and Irregular-Shaped Cells

ADAM-MC2 provides accurate and reliable results because it counts aggregated and irregular-shaped cells.

  • Accurate count based on cell size and shape
  • Count aggregated cells individually
  • Debris is excluded from results

Among the images on the left, the images on the right side indicate cells that have been counted by ADAM-MC2.

ADAM MC2 - a new standard of Automated Cell Counter

Cell Therapeutic Applications

ADAM-MC2 can be used as a device for monitoring and QC of the cell numbers and viability in the process of manufacturing cells (CAR-T cells, stem cells, etc.) for Cell Therapy. In addition, it is possible to use ADAM-MC2 depending on the cell types (Whole blood cell, PBMCs, etc.) that needs to be monitored during the manufacturing of cell therapy products.

ADAM MC2 - a new standard of Automated Cell Counter

Accuracy & Repeatability

Correlation of total cell counting between hemocytometer and ADAM-MC2 using SH-SY5Y cells.

ADAM MC2 - a new standard of Automated Cell Counter

Accuracy & Repeatability

Sample with low, medium and high concentration of cells were counted with ADAM-MC2. The repeatability at each level of cell concentration is high.

ADAM MC2 - a new standard of Automated Cell Counter

Comparison for Cell Viability

Comparison of cell viability between ADAM-MC2, flow cytometry, and manual counting.

SH-SY5Y, Jurkat, HeLa cells were treated with 100, 300M HO for 3 hours, then analyzed by ADAM-MC2, flow cytometry, and manual counting.

ADAM MC2 - a new standard of Automated Cell Counter

Supplier

NanoEntek Inc.
show all products

Specifications

Focus

Auto-focusing

LED

4W Green LED

Weight

7 kg

Size (L x W x H)

227x276x270mm

Accessories

650.00 CHF
650.00 CHF
Art No | ADR-1000
Accustain Solution (1000 tests)

Size: 1 Kit

380.00 CHF
380.00 CHF